Temperature/Humidity/Vibration Integrated Test Chamber
Product Usage :Temperature/Humidity/Vibration Integrated Test Chamber offer rapid temperature change rates with combined temperature, humidity, and/or vibration environments. All models are designed for compatibility with your choice of electrodynamic or mechanical vibration systems. While each model is manufactured to standard designs, they may also be custom engineered to meet a wide range of stringent test requirements.The CVTH Series temperature/humidity and vibration chambers was originally designed to perform specific temperature, humidity, and vibration tests in order to improve the quality and reliability of military hardware and to conform with MIL-STD 781 and 883.Chambers may also be used as temperature cycling chambers without vibration utilizing a solid floor plug.
Apply to:Temperature humidity Vibration integrated test
Customizable :Specific product specifications and parameters can be customized according to the customer's actual situation or customization. You can contact us at any time to obtain quotations and solutions.
Parameter Details
Sizes of Temperature humidity Vibration integrated test Chambers | |||||
Model
|
Volume (L)
|
Temperature Range
(°C) |
Rated Power
|
Internal Dimension (mm) D*W*H
|
External Dimension (mm) D*W*H
|
LRHS-101B-CVTH
|
101
|
A: -20~150°C
B: -40~150°C C: -60~150°C D: -70~150°C E: or customized |
4.0kw
|
450*450*500
|
1160*1000*1610
|
LRHS-225B-CVTH
|
225
|
4.5kw
|
500*600*750
|
1210*1150*1870
|
|
LRHS-504B-CVTH
|
504
|
7.0kw
|
700*800*900
|
1260*1340*2070
|
|
LRHS-800B-CVTH
|
800
|
9.0kw
|
800*1000*1000
|
1370*1550*2170
|
|
LRHS-1000B-CVTH
|
1000
|
11.5kw
|
1000*1000*1000
|
1560*1550*2170
|
|
Note: In the Model, the number means volume of test chamber's working room, and ABCD means the temperature range. For example, model LRHS-101B-CVTH means the volume of this test chamber is 101L, and its temperature range is -20°C~+150°C. LRHS-225C-CVTH means the volume is 225L and the temeprature range is -60°C~+150°C |
|||||
Basic Specification | |||||
Performance
|
Temperature Range | A: -20~150°C, B: -40~150°C, C: -60~150°C, D: -70~150°C, E : or customized | |||
Temperature Fluctuation | ±0.5°C | ||||
Temperature Uniformity | ±2.0°C | ||||
Humidity Range | 20%-98% RH | ||||
Vibration table size | 30*30cm | ||||
Frequency range | 5 to 3500 Hz | ||||
Push force | 10KN | ||||
Peak to peak | 40mm | ||||
Vibration direction | up and down | ||||
G value | 1000 m/s2 | ||||
Ramp Rate | 1~3°C/min for heating (non-linear, based on on-load) 0.7~1.0°C/min for cooling (non-linear, based on on-load) Note: can be customized as per requirement |
||||
Material
|
External Casing | Cold-rolled A3 (Q235) steel plates with plastics painted. | |||
Interior Working Room | Stainless Steel Plates SUS304 with miror surface | ||||
Heat Isolation | Polyurethane foams and fine glass fibres | ||||
Illumination Lamp | Philips® one in per standard test chamber. | ||||
Casters | 4pcs, with PU covered for protection. Height adjustable and direction universal. | ||||
Viewing Window | Multi-layer hollow toughened glass with conductive films for heating to defrost | ||||
Heating & Cooling System
|
Heater | Steipped Nickel-chromium Wire Heater | |||
Air Blower | Anti-temperature stainless fan blades with low noise | ||||
Compressor | Hermetically-sealed Techmesh® or semi-sealed Bitzer® or GEA® or equivalent compressors | ||||
Refrigerant | R404A or/and R23 (eco-friendly) | ||||
Condenser | Plate-type heat exchanger | ||||
Control System
|
Controller | 7" Programmable colorful touch-screen display LCD English Display Microcomputer integrated controller |
|||
Functions | Data Record (Max 600 days x 24hrs), History Curve, USB data download & upload, Remote controlling through PC, Automatic protection alarms, etc. | ||||
Program | 1~1000 programs, 1~999 steps for per program, Max 99hrs 59mins for per program. 10 programs can be interlinked. | ||||
Temperature Sensor | Platinum Resistance.PT100Ω | ||||
Running Model | Constant/Fix-value Model and Programmable Model | ||||
I/O Interface | Communicate port (RS485) to connect test chamber to a PC | ||||
Standard Configuration | Test Chamber x 1, Specimen Holder Shelf x 2, φ100mm Cable Access Port x 1 with 1 soft plug, EMO x 1, Tri-color Indicator x 1, etc. | ||||
Safety Protection | Power leakage protection/Compressor over-heat, over-load or over-current protection/Dry burning protection. | ||||
Voltage | 380V/440V±10%, 50Hz/60Hz or as per requirement | ||||
Ambient Enviromental for application | 5°C~+30°C ≤ 85%R.H | ||||
Test Standards (not limited to) |
Feature
2. Custom Sizes Available 3. Touch Screen Programmer
4. User-Friendly Controls 5. Running time meter
6. Wide temperature and humidity ranges
7. Balanced load on 3 phase power.
8. Multipane tempered heated window.
9. Incandescent interior lighting
10. Tri-color Indicator and EMO (Emergency-off Switch) available.
11. Stainless steel interior
12. Painted galvanized steel exterior for long life
13. Mechanical cooling
14. Comprehensive safety features
15. All circuits fused or circuit breaker protected.
16. All wiring numbered or color coded
17. Compressor overload protection
18. Viewing windows
Test standard
Submit your requirements
Application
Scope of application-
New Energy
Test chambers have extensive applications in the n… -
Rubber products
Before rubber products leave the factory, it is es… -
Electronic and electrical products
The purpose of environmental testing for electrica… -
Automotive Industry
The automotive industry must conduct numerous envi… -
Aerospace and Defense Industry
As aerospace technology advances and the defense i…