Parameter Details

 Device model LRHS-22.5M-QDC
 Studio size 3000mm×3000mm×2500mm (width×depth×height)
 Dimensions 3200mm×3920mm×2780mm (width×depth×height), excluding motor height
 Unit size About 2600mm×2500mm×2080mm×1 set (width×depth×height)
 Power cabinet size About 1000mm×800mm×2080mm×2 sets (width×depth×height)
 Hydrogen system dimensions Approximately 4320mm×2300mm×2080mm (width×depth×height), excluding motor height
 Air system dimensions Approximately 5020mm×2500mm×2080mm (width×depth×height), excluding motor height
 Power cabinet size About 800mm×600mm×2080mm×5 sets (width×depth×height)
Performance  temperature range   -50℃~+100℃【Meet static storage requirements】

-40℃~85℃ [Meet heat load requirements, up to 150kW heat dissipation]
 Humidity range 10%~95%RH (within the range of 10℃~85℃) [static no heat load]

At 65℃, the response time for humidity from 10% to 95% does not exceed 100min [static no heat load]

  Temperature and humidity 60℃/90%RH [heat load 150kW]
 Temperature control accuracy ≤±1℃ [when the engine is not running], ≤±3℃ [when the engine is running, maximum heat dissipation is 150kW]
 temperature fluctuation ≤±0.5℃ [no load], ≤±3℃ [with load 150KW]
 temperature uniformity  ≤2.0℃【When the engine is in the cabin without heat dissipation】
 Humidity control accuracy  Within ±5%RH [no load]
 Humidity fluctuation  ≤±5%RH【no load】
 Heating rate -40℃~+85℃, the average speed of the whole process is 1℃/min [540kg electric stack is placed inside, and the heat dissipation is 150KW]
 cooling rate +85℃~-40℃, the average speed of the whole process is 1℃/min [540kg electric stack is placed inside, and the heat dissipation is 150KW]
 Customer testing product Test product: metal fuel cell stack engine + total weight: 540kg + stack power: 150kw
Material  Outer box material High-quality cold-rolled steel plate (t=1.0mm), surface electrostatic spray treatment
 Inner box material  Stainless steel plate (SUS304-CP 2B grinding)
 Base material Welding of anti-slip stainless steel plate (SUS304) t=3.0mm. Bottom plate load-bearing requirement: greater than 2T/mP2
 Insulation material  150mm rigid polyurethane foam insulation layer
 flashlight Explosion-proof LED lights are moisture-proof, explosion-proof, transparent, heat-insulating, and not prone to steam frosting, etc.
Basic Specification  controller  Imported "Youyikong" brand temperature and humidity meter
 Cooling System  German "BITZER" semi-hermetic air-cooled/water-cooled compressor refrigeration method
 Temperature Sensor  High-precision Pt100 platinum resistance temperature sensor
 Humidity Sensor High-precision Finnish Vaisala "vaisala" capacitive humidity sensor
 Pressure relief hole Equipped with an electric pressure balance device to maintain a slight positive pressure ranging from 0 to 50Pa in the environmental chamber under any circumstances.
 Blower  Single suction multi-blade centrifugal explosion-proof fan, adjustable frequency
 safe calling system There is a call system inside the box, which is convenient for calling in case of emergencies and ensures the safety of the staff inside in emergencies.
 Optional accessories Pump-type explosion-proof hydrogen/oxygen concentration alarm system, smoke concentration alarm, access control system, explosion-proof sink pressure protection device, visual monitoring system, etc.
 safety protection Compressor low pressure/overload/high pressure alarm, hydrogen/oxygen/smoke concentration alarm, fan overload, system abnormality alarm, emergency stop switch, water shortage, short circuit, phase loss, over-temperature and other protections
 voltage AC380V±10% 50Hz
 total power   Maximum load capacity is about 270KW, maximum current: 480A
  Hydrogen system power is about 138KW, maximum current: 240A
  Air system power is about 165KW, maximum current: 290A
  Total air switch capacity 1500A
product

Feature

1. Modern attractive styling
2. Large double doors/Viewing windows
3. Custom Sizes Available. 4. Touch Screen Programmer
5. User-Friendly Controls. 6. Wide temperature and humidity ranges
7. Capable of handling extreme temperature and humidity
8. Tri-color Indicator and EMO (Emergency-off Switch) available.
9. High performance even under load
10. Modular,Robust Reliable construction
11. Painted galvanized steel exterior for long life
12. Heavy-duty flooring to support vehicles. 13. Mechanical cooling
14. Comprehensive safety features. 15. Refrigeration gauges
16. Refrigeration sound deadening package
17. Low or zero ozone depletion refrigerants
18. All circuits fused or circuit breaker protected.
19. All wiring numbered or color coded
20. Compressor overload protection
21. Prefabricated for On-Site Installation